Eastdale Collegiate Institute

Facility Condition Index

2022 -2023

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the building.

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.


F.C.I.
71.22 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies approximately 20,400 different repairs needed in our schools. The total value of those repairs was $4.2 billion as of March 2023.

For the 2022-2023 school year, the TDSB  received $292 million in provincial funding. These funds will be used to replace/repair building components identified during the Ministry’s school inspections, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).
Brief DescriptionPriority
Auxiliary Equipment - Expansion tanks RenewalUrgent
B201011 Exterior Walls - Joint Sealant RenewalUrgent
B3010 Roof Coverings - Section A Localized Deficiencies RenewalUrgent
D202001 Domestic Water Distribution - Pipes and Fittings RenewalUrgent
D2030 Sanitary Waste RenewalUrgent
D2040 Rain Water Drainage RenewalUrgent
D306003 Controls and Instrumentation - Pneumatic RenewalUrgent
Elevators & Lifts - Traction Elevator RenewalUrgent
Exterior Walls - 1962 Building RenewalUrgent
Exterior Walls - Masonry RenewalUrgent
Exterior Windows - Original 1962 remaining RenewalUrgent
Floor Finishes - Sheet Vinyl - Classrooms RenewalUrgent
Floor Finishes - Vinyl Tile - Classrooms RenewalUrgent
G30 - Underground Utilities RenewalUrgent
Heating/Chilling Water Distribution Systems - 1962 Building RenewalUrgent
Interior Stair Construction - 1962 Building RenewalUrgent
Standard Foundations - Localized Deficiencies RenewalUrgent
Terminal & Package Units - Perimeter Heating Radiators - 1962 Building RenewalUrgent
Ceiling Finishes - Acoustic Tiles RenewalHigh
D201001 Plumbing Fixtures - Water Closets RenewalHigh
D201003 Plumbing Fixtures - Lavatories RenewalHigh
D502001 Lighting and Branch Wiring - Branch Wiring RenewalHigh
D502004 Lighting and Branch Wiring - Exterior Lighting - Wall Mounted RenewalHigh
Exhaust Systems - 1962 Building RenewalHigh
Exterior Doors & Hardware RenewalHigh
Fencing & Gates - Chain Link Fence RenewalHigh
Fencing & Gates - Concrete Stairs RenewalHigh
Fencing & Gates - Wrought Iron Fence RenewalHigh
Fittings - Lockers RenewalHigh
Fittings - Millwork RenewalHigh
Fittings - Partitions - Metal RenewalHigh
Floor Finishes - Hardwood Floor - Gym & Stage RenewalHigh
Floor Finishes - Terrazzo - Corridors RenewalHigh
G303007 Stormwater Management RenewalHigh
Interior Doors & Hardware RenewalHigh
Parking Lots - Original Building RenewalHigh
Pedestrian Paving RenewalHigh
Playing Fields - Field - Unpaved RenewalHigh
Signage RenewalHigh
Wall Finishes - Painted - 1962 Building RenewalHigh
Landscaping - Front Entrance RenewalMedium
Partitions - Concrete Block - Localized Deficiencies RenewalMedium
Partitions - Moveable - General Purpose Room RenewalMedium