Toronto District School Board
Toronto District School Board
Icon - Find Your School  Find Your School|Newcomers|Policies|Media
About Us|Staff|Innovation|Leadership|Contact Us
Translate
Close Window X

Google Translate Limitations Disclaimer

The electronic translation service on the Toronto District School Board website is hosted by Google Translate, a third party service. The TDSB does not guarantee or warrant the reliability, accuracy or completeness of any translated information.

The quality of the translation will vary in some of the languages offered by Google. Google Translate is a free service and currently offers translation in over 100 languages, but does not capture all languages or dialects.

The basic translation goal is to capture the general intention of the original English material. Before you act on translated information, we encourage you to confirm any facts that are important to you or may affect any decisions you make.

The Toronto District School Board is committed to equity and community engagement, and by providing this tool, we are making our information more accessible to families whose first language is not English.

Google Translate Frequently Asked Questions

TDSB Search  Search

Winston Churchill Collegiate Institute

Facility Condition Index

September 1, 2017 to August 31, 2018

The Facility Condition Index (FCI) rating is a measurement of the condition of a school building. It does not reflect on the safety of the school building. 

The health and safety of students, staff and community members are our top priority when planning school repairs. Our Facility Services staff works year-round to ensure our schools are safe regardless of their FCI rating.

Almost half of the 584 TDSB school buildings were built more than 60 years ago. Older schools often have a higher FCI rating as some building components such as walls, lights, floors and ventilation systems may require major repairs or replacement.

F.C.I.
69.06 %

Learn More

Learn more about the Renewal Needs Backlog and the Facility Condition Index, both of which include related Frequently Asked Questions.

Renewal Needs Backlog

The Toronto District School Board’s Renewal Needs Backlog (RNB) list identifies 22,686 different repairs needed in our 584 schools. The total value of those repairs is approximately $3.7 billion as of September 2017. 

For the 2017-2018 school year, the TDSB received $297 million in provincial funding. From this amount, $50 million should be used to replace energy efficient building components. The remaining $247 million should be used to replace/repair building components identified during the schools inspection, helping reduce the FCI of school buildings.

It is important to understand that these repairs do not represent a health or safety concern. Safety is a top priority for us at the TDSB and our maintenance plans are always focused on providing safe places for our students and staff. In order to do that, we fix the most critical problems related to health and safety first. Also, while components in a school building may be past their life expectancy (e.g. water boiler), they are in good condition and meet all required safety codes.

Legend

Urgent Building systems that are in critical condition and have surpassed their useful service life. These systems are very important to the operation of the building (e.g. boilers, other heat generating systems, fire alarm, sprinkler system, standpipe system, public address system, roofing, etc.). Although there is no specific timeframe to repair/replace these systems, it is recommended to do it as soon as funding becomes available.
High Building systems that are in critical or poor condition and their importance to the operation of the building is less than those classified as “urgent” (e.g. brick work, exterior doors, exterior windows, rooftop units, etc.). There is no specific timeframe to repair/replace these systems; however, repair/replacement is recommended as soon as funding becomes available.
Medium Building systems that are in fair condition with low importance to the operation of the building (e.g. floor finishes, washroom partitions, millwork, etc.).
Low Building systems that are in fair or good condition with very low importance to the operation of the building (e.g. wall partitions, interior wall finishes, interior doors, fences, etc.).

.Study [Site Civil/Mechanical Utilities - Site]Urgent
Auxiliary Equipment - Expansion Tanks RenewalUrgent
Auxiliary Equipment - HVAC and Condensate Pumps/Tanks RenewalUrgent
Auxiliary Equipment - Heat Exchangers 2 RenewalUrgent
Heating/Chilling water distribution systems - Remaining 70% RenewalUrgent
Interior Stair Construction - Steel and Terrazzo Stairs RenewalUrgent
Roof Coverings - Section B1,C1,C4 RenewalUrgent
Roof Coverings - Section C2,C6,D,D1,E1,F,H1,H2,I1,J RenewalUrgent
Site Civil/Mechanical Utilities - Site RenewalUrgent
Standard Foundations - Parging - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalUrgent
Study [Heating/Chilling water distribution systems - Remaining 70%]Urgent
.Study [Structural Frame - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7]High
Branch Wiring RenewalHigh
Ceiling Finishes - Acoustic Tiles Ceiling - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Ceiling Finishes - Suspended Acoustic Panel Ceiling- Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Clock and Program Systems RenewalHigh
Controls & Instrumentation - Compressor RenewalHigh
Controls & Instrumentation - Pneumatic Control RenewalHigh
Domestic Water Distribution - Plumbing Piping System RenewalHigh
Exhaust Systems - Remaining 30% RenewalHigh
Exterior Doors - Hardware - Original Building & Addition 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Exterior Doors - Hollow Metal Doors - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Exterior Doors - Overhead Doors RenewalHigh
Exterior Walls - Sealant - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Exterior Walls - Solid Brick - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Fencing & Gates - Chain Link Fencing - Site RenewalHigh
Fittings - Gymnasium Bleachers - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Fittings - Metal Lockers - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Floor Finishes - Carpet - Library, Drama and Office RenewalHigh
Floor Finishes - Hardwood - Gymnasium and Wood Shop RenewalHigh
Floor Finishes - Painted Concrete Floor RenewalHigh
Floor Finishes - Vinyl Tile - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Interior Doors - Hardware - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Interior Doors - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Lighting Equipment - Exterior [GPL1] RenewalHigh
Major Repair [Floor Finishes - Terrazzo - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7]High
Major Repair [Structural Frame - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7]High
Other Cooling Generating Systems - Cool [2] Keep Rite unit RenewalHigh
Other Heat Generating Systems - Make - Up AHU RenewalHigh
Other Special Systems and Devices-Auto Hoists RenewalHigh
Other Special Systems and Devices-Compressed Air Systems RenewalHigh
Parking Lots - Asphalt - Site RenewalHigh
Pedestrian Paving - Asphalt - Site RenewalHigh
Pedestrian Paving - Poured Concrete - Site RenewalHigh
Playing Fields - Field & Gravel Track - Unpaved RenewalHigh
Plumbing Fixtures - Rest of the building RenewalHigh
Roadways - Driveway & Drop off - Site RenewalHigh
Signage - Wall-mounted and Lawn Signs - Site RenewalHigh
Study D2020 Domestic Water Distribution - Plumbing Piping System]High
Study [Terminal & Package Units - Unit Heaters]High
Terminal & Package Units - Unit Heaters RenewalHigh
Terminal & Package Units - Unit Ventilators RenewalHigh
Wall Finishes - Painted - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalHigh
Auxiliary Equipment - Staks & Breaching RenewalMedium
Emergency Lighting & Power - Original Building RenewalMedium
Emergency Lighting & Power RenewalMedium
Fittings - Millwork - Original Building & Additions 1, 2, 3, 4, 5, 6 and 7 RenewalMedium
Fittings - Washroom Partition - Hollow Metal RenewalMedium
Main Switchboards - West Wing RenewalMedium
Other Special Systems and Devices - Sawdust Collector RenewalMedium
Partitions - Moveable - Gymnasium RenewalMedium
Sprinklers RenewalMedium
Wall Finishes - Ceramic Wall Tiles - Washrooms RenewalMedium
Air Distribution, Heating & Cooling - Duct System RenewalLow
Air Handling Units - Office RenewalLow
Domestic Water Distribution - Sump Pumps RenewalLow
Domestic Water Distribution- Backflow Preventer RenewalLow
Exterior Doors - Replace Doors & Frames RenewalLow
Fittings - Walk-In Freezer RenewalLow
Lighting Equipment - Exit Lighting RenewalLow
Lighting Equipment - HID RenewalLow
Other Communications & Alarm Systems RenewalLow
Playing Fields - Unpaved RenewalLow
Playing Fields - Upgrade Surface - Unpaved RenewalLow
Security Systems - Original Building RenewalLow